Humidity-variable sealing strip

INTELLO conneX

Advantages

  • Time-saving installation: vapour check strips are pre-cut
  • Also suitable for building components with short-term moisture loading
  • Construction in adherence with standards: for airtight sealing in accordance with DIN 4108-7, SIA 180 and RE 2020
  • Protection in rough everyday building site environments thanks to robust fleeces
  • Excellent protection for building components thanks to humidity-variable diffusion resistance
  • Excellent values in hazardous substance testing, has been tested according to the ISO 16000 evaluation scheme

Areas of application

Strip for sealing over joints, e.g. at floor joints with concrete floors/ceilings, on wood-based panels, for use on the middle purlin (between middle purlin and rafters) for sealing joints with adjacent airtight membranes, or as a repair strip for sealing leaks on roofs, walls, ceilings or floors.

Technical specs

  Material
Protective and covering fleece Polypropylene
Functional film Polyethylene copolymer
Property Value Regulation
Colour Light grey
Surface weight 150 g/m² ; 0.45 oz/ft² EN 1849-2
Thickness 0.45 mm ; 18 mils EN 1849-2
Water vapour resistance factor µ 31 100 EN 1931
sd value 14 m EN 1931
sd value, humidity-variable 0.25 - >25 m EN ISO 12572
g value 70 MN·s/g
g value, humidity-variable 1.25 - >125 MN·s/g
Vapour permeance 0.23 perms ASTM E96-A
Vapour permeance, humidity-variable < 0.13 - 13 perms EN ISO 12572
Hydrosafe value (sd) 2 m DIN 68800-2
Surface burning characteristics ASTM E84
Fire class E EN 13501-1
Outdoor exposure 2 months
Driving rain test Passed ZVDH
Watertightness to liquid water W1 EN 1928
Water column > 2 500 mm ; > 8' 2" EN ISO 811
Airtightness Tested EN 12114
Tensile strength MD/CD 250 N/5 cm / 170 N/5 cm ; 29 lb/in / 19 lb/in EN 12311-2
Elongation MD/CD 60% / 60% EN 12311-2
Nail tear resistance MD/CD 120 N / 120 N ; 27 lbf / 27 lbf EN 12310-1
Durability after artificial ageing Passed EN 1296
Temperature resistance Permanent -40 °C to 80 °C ; -40 °F to 176 °F
Thermal conductivity 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F)
CE labelling Yes EN 13984