Flame-resistant breather membrane (WRB) for open-jointed cladding, gap width up to 35 mm (1 3/8")

connect variant with self-adhesive strips

Advantages

  • Improved safety: 'not easily flammable', fire classification B-s1, d0 as per EN 13501-1
  • Well-protected building components: highly permeable and, at the same time, maximum protection against driving rain
  • Not visible behind open-jointed cladding: black fleece with printed marking only in the overlap area
  • Highest possible durability and thermostability thanks to the monolithic functional film
  • 6 months of outdoor exposure

Areas of application

For use as a breather membrane (weather-resistive barrier, WRB) behind closed and open facades (open-jointed cladding up to a gap width of 35 mm (1 3/8"); cladding width = at least 3 x gap width). Installation onto boarding, wood-based panels and all mat or panel-shaped thermal insulation materials.

Installation instructions

Installation video

General conditions

SOLITEX FRONTA QUATTRO FB membranes should be installed with the black side facing outwards. The membranes are to be installed horizontally in a taut manner with no sagging.

When the product is used behind open-jointed cladding, the gap may be a maximum of 35 mm (1 3/8"). The width of cladding pieces must be at least three times the gap width. The distance between the open-jointed cladding and the membrane must be at least 20 mm (3/4").

Fasteners may not be applied in areas where water run-off is collected.

Additional measures (e.g. covering with tarpaulins) should be taken during the construction phase in the case of buildings that are lived in or buildings that are to be given particular protection. Covering with tarpaulins should also be considered if construction work is to be interrupted for a longer period.



Building projects with SOLITEX FRONTA breather membranes (WRBs) for open-jointed cladding